Module function description
1) In water meter mode, when battery voltage goes under 3.2V the system will prohibit valve opening operation and periodic data uploading function. When battery voltage goes over 3.2V, the buzzer will beep and the system will return normal.
2) The module reads the battery voltage once every 24 hours.
3) Magnetic interference valve closing function. When a double reed switches meter encounters magnetic interference, the system will close the valve immediately. After disappearance of magnetic interference, the valve will remain closed for a specific period of time (according to configuration) and then be opened.
4) When one of the reed switches is broken, the system will lock the counting function and enable the fault status.
5) Transmit power testing function. When the module receives transmit power testing command, it begins to transmit continuously high level signal for 5 seconds. This function only exists in the "System Administrator" subdirectory of HUU (Hand Held Unit), only for system debugging.
6) The module has periodic data uploading function based on time or volume. The period of time is 24 hours. The period of volume counted is 1 m3.
7) Routing function: please refer to the user manual of HUU.